Sussex Stable Session Workflow

Converts the verified Sussex command findings into a repeatable operator checklist, guardrails, and implementation plan for the remaining GUI and data-collection features.

Sussex Stable Session Workflow

This page freezes the current best-known Sussex operator path after the March 2026 Quest, task-pinning, and GUI verification passes. The goal is to reduce run-to-run variability by turning the verified findings into one fixed operator workflow with explicit hazards and a concrete implementation backlog.

Stable Operator Rules

  • Use ADB and hzdb for connectivity, install, device-profile setup, screenshot capture, and verified study commands.
  • Do not use GUI-driven or shell-injected sleep and wake as the normal participant handoff path. Use the physical headset power button for between-operator and between-participant sleep and wake transitions.
  • Use the direct prox_close keep-awake override through Sussex launch and the pre-session guide on this build. Restore normal wear-sensor behavior with automation_disable when the live session is done.
  • Treat the raw Quest readback literally:
    • Virtual proximity state: CLOSE means the keep-awake override is active.
    • Virtual proximity state: DISABLED means normal wear-sensor behavior is active again.
  • Wake the headset before launch. Do not launch Sussex while the headset reports asleep; on the current April 2026 Meta OS build that can leave the runtime running in a black or limbo scene that may require a headset restart.
  • Do not use remote GUI wake/sleep controls for Sussex. Manual headset wake/sleep is the only supported operator path for now.
  • Do not launch until the right controller is awake and tracked.
  • Do not treat the launch path as a reliable right-controller Meta / menu button lockout on the current April 2026 Meta OS build. Treat it as best-effort task pinning plus screenshot-confirmed foreground only.
  • Do not allow an experimenter's bench calibration to survive into the participant run. Calibration intentionally performed in the Experiment Session window before Start Recording is participant calibration and must survive the recording start command.
  • Keep the Sussex APK running across participants unless a real failure requires a runtime stop or restart.

Fixed Session Workflow

1. Pre-session readiness with USB attached

  1. Connect the headset by USB to establish a trusted ADB path.
  2. Probe USB, enable Wi-Fi ADB, and switch the shell onto a working Wi-Fi ADB endpoint.
  3. Apply the pinned Sussex device profile.
  4. When implemented and verified, apply the pinned Sussex brightness and volume values.
  5. Verify that the staged Sussex APK matches the pinned hash.
  6. Verify that the installed headset APK matches the pinned hash. Install or update it if it does not.
  7. Verify that the headset software version, build id, and display id still match the recorded verified Sussex baseline.
  8. Verify that headset battery and right-controller battery both meet the study threshold.
  9. Verify that the right controller is connected and active.
  10. Show a single study-ready state only after all checks pass.

Important: USB can stay attached for setup, but the readiness state should explicitly prefer a live Wi-Fi ADB transport before continuing.

2. Boundary plus runtime launch by the experimenter

  1. Disconnect USB.
  2. The experimenter puts on the headset in the subject position.
  3. Create or confirm the Guardian boundary.
  4. Wake the headset if needed. The launcher should read Wake the headset to enable launching until the headset is awake.
  5. Disable proximity before launch. The current launch path also auto-arms the keep-awake override, but the guide should still show its state explicitly. Expect CLOSE while the override is active and DISABLED after you restore normal proximity.
  6. Wake the right controller if needed and verify it is active before launch.
  7. Launch Sussex from the GUI.
  8. If Guardian or another Meta visual blocker is still visible, clear it before launching.
  9. Do not use controller Meta / menu-button behavior as the launch-success signal on this build.
  10. Confirm the visible scene on-headset. If shell focus and the visible scene disagree, use one Quest screenshot as the source of truth.

3. Bench verification before subject handoff

  1. Verify the Unity command path by sending Particles Off, Particles On, and Recenter.
  2. Verify that the study LSL inlet is connected and visible in the GUI.
  3. Keep the headset on-face or leave the keep-awake proximity override active while probing. Otherwise the return path can go stale between steps.
  4. Start controller breath-volume calibration from the GUI.
  5. Finish calibration and visually confirm that the runtime behaved as expected.
  6. Send a dedicated Reset Calibration GUI command so the experimenter's calibration cannot leak into the participant run.
  7. Send Particles Off.
  8. Place the headset in the exact starting position for the participant.
  9. Put the headset to sleep with the physical power button.

4. Participant start

  1. When the participant is ready, wake the headset with the physical power button.
  2. Open the dedicated Experiment Session window if it is not already open.
  3. Send Particles On.
  4. Send Recenter.
  5. Ask the participant to confirm the view.
  6. Capture one Quest screenshot as an operator-side confirmation.
  7. Enter the participant number in the Experiment Session window.
  8. If the participant number already exists on this Windows machine, show a warning but do not block the run.
  9. If the run uses controller breathing, start dynamic-axis or fixed-axis controller calibration from the Experiment Session window and wait for the runtime to accept it.
  10. Press Start Recording.
  11. Start Recording should:
  • stamp participant and session metadata
  • reset stale recorder state only, not controller calibration
  • preserve the current participant controller calibration
  • trigger the headset-side experiment start path
  • start companion-side data capture immediately
  1. Keep the Experiment Session window open for the running session.

5. Participant end

  1. Press Stop Recording in the Experiment Session window.
  2. Stop Recording should:
    • stop companion-side data capture
    • send the headset-side stop and end command
    • pull the Quest-side backup into device-session-pull
    • report Quest backup pullback timeout/cancel as a pullback warning while preserving the Windows session folder and stopped recorder metadata
    • send Reset Calibration
    • send Particles Off
    • write final session metadata to disk
    • generate session_review_report.pdf
  3. The experimenter removes the headset from the participant.
  4. Put the headset to sleep with the physical power button.
  5. Return to the participant-number entry state without forcing a runtime stop, so the next participant can reuse the same prepared runtime.

6. Exception path

  • If launch or stop reaches only shell-level confirmation, require a Quest screenshot review before proceeding.
  • If Guardian, SensorLock, or FocusPlaceholder blockers appear, use the recovery notes and physical power-button path instead of trying to automate around them inside the normal session workflow.
  • If the study runtime contract needs new telemetry keys or new calibration, start, or stop commands, implement that in the participant-facing runtime first and then refresh the mirrored Sussex APK here.

Missing Features To Build

Repo-side features in this repo

  1. Fixed workflow state machine in the Sussex shell

    • Add explicit phases such as Setup, Boundary, BenchCheck, ParticipantReady, Running, and WrapUp.
    • Gate buttons so only the next safe actions are prominent.
    • Replace the current loose checklist feel with a derived readiness panel and a current-step banner.
  2. Readiness gate and greenlight model

    • Compute a single Ready For Runtime and Ready For Participant state from:
      • Wi-Fi ADB connected
      • pinned APK hash verified
      • pinned device profile active
      • verified OS, build, and display baseline match
      • headset battery above threshold
      • controller battery above threshold
      • right controller connected and active
    • Keep duplicate detail visible in Inspect, but keep the main Sussex shell binary: blocked or ready.
  3. Participant and session controls

    • Add a participant-number field in the Sussex shell.
    • Warn on duplicate participant numbers found under the local study-data root.
    • Add Start Experiment, End Experiment, Start Calibration, and Reset Calibration commands and actions to the study shell.
    • Keep Particles On, Particles Off, Recenter, and Capture Quest Screenshot visible as secondary tools, not the main workflow driver.
  4. Brightness and volume device controls

    • Extend IQuestControlService and WindowsAdbQuestControlService with dedicated brightness and volume setters after device-level write and readback is verified.
    • Add those values to the pinned Sussex device profile or to a study policy block.
    • Do not gate the stable workflow on them until they have live readback coverage and repeatable tests.
  5. Companion-side recording service

    • Add a dedicated study recorder service instead of overloading SessionManifestWriter.
    • Start and stop it from the Sussex shell commands.
    • Store one folder per participant session under the current operator-data root under ...\ViscerealityCompanion\study-data\sussex-university\<participant>\<session-start-utc>\.
  6. Session settings snapshot

    • Write one immutable settings snapshot per participant run.
    • Include:
      • participant number
      • session start and end timestamps
      • study id and app version
      • APK hash, package id, and version
      • headset OS, build, and display ids
      • pinned device profile id and applied values
      • brightness and volume values once supported
      • active LSL stream name and type
      • operator-facing threshold values used by the gate
      • Windows machine name and current Quest selector
  7. Recording UX and failure handling

    • Show clear Idle, Armed, Recording, Stopping, and Faulted recorder states.
    • If data capture cannot start, block Start Experiment.
    • If a duplicate participant id is detected, warn but allow explicit continue.
    • If writing fails mid-run, surface a hard failure banner and append an operator log entry.
  8. Tests and harness coverage

    • Unit tests for readiness-gate logic, duplicate-id detection, session-folder naming, and data-row formatting.
    • Integration tests for recorder start and stop behavior and settings snapshot generation.
    • Extend the Sussex verification harness to cover new calibration, reset, start, and end commands once the runtime exposes them.

Runtime-side features in the participant-facing runtime first, then mirror the APK here

  1. New twin commands and control ids

    • Start Calibration
    • Reset Calibration
    • Start Experiment
    • End Experiment
    • Optional explicit Finish Calibration or Abort Calibration if the calibration flow is not fully self-contained
  2. New published telemetry required for recording

    • headset position and rotation
    • controller position and rotation
    • heartbeat packet arrival and value
    • coherence value routed from the LSL heartbeat packets
    • breathing volume
    • sphere-radius progress
    • raw sphere radius
    • explicit runtime and session state markers for calibration started, calibration completed, experiment started, and experiment ended
  3. Participant and session metadata sink

    • The runtime needs a way to receive the participant number and any session id that should be embedded in headset-side outputs or markers.
    • If that metadata should be visible in quest_twin_state, define the key names explicitly.
  4. Telemetry contract stabilization

    • Freeze the public key names used by the Sussex shell and recorder before rolling the data pipeline out to real participants.
    • Avoid renaming keys between APK drops once recording has begun.

Recommended Data Layout

Use a per-participant folder plus row-oriented long tables, not one wide, evolving CSV. The row shape should stay stable across signals.

Folder shape

<operator-data-root>\study-data\sussex-university\
  participant-0007\
    20260329T141530Z\
      device-session-pull\
      session_snapshot.json
      session_settings.json
      session_events.csv
      signals_long.csv
      breathing_trace.csv
      session_review_report.pdf
      quest_screenshot_prestart.png

signals_long.csv

Write one row per fixed companion sampling tick. Do not suppress unchanged values during a run. Recommended columns:

  • participant_id
  • session_id
  • recorded_at_utc
  • source_timestamp_utc
  • lsl_timestamp_seconds
  • source
  • signal_group
  • signal_name
  • value_numeric
  • value_text
  • unit
  • sequence
  • quest_selector

Minimum signals to record here:

  • headset position x, y, z
  • headset rotation qx, qy, qz, qw
  • controller position x, y, z
  • controller rotation qx, qy, qz, qw
  • heartbeat packet values
  • coherence values carried by those packets

recorded_at_utc should always be the companion write time. When available, also persist the source-side timestamp separately instead of collapsing everything into one field.

breathing_trace.csv

Keep the breathing-specific trace separate because it will likely be denser and frequently analyzed on its own.

Recommended columns:

  • participant_id
  • session_id
  • recorded_at_utc
  • source_timestamp_utc
  • breath_volume01
  • sphere_radius_progress01
  • sphere_radius_raw
  • controller_calibrated

session_events.csv

Capture workflow and command markers as discrete events:

  • participant number entered
  • duplicate-id warning shown
  • runtime launched
  • particles on and off
  • recenter sent
  • calibration started
  • calibration reset
  • experiment started
  • experiment ended
  • recording started and stopped
  • physical screenshot captured

Recommended columns:

  • participant_id
  • session_id
  • recorded_at_utc
  • source_timestamp_utc
  • event_name
  • event_detail
  • command_action_id
  • result

session_settings.json

This is the immutable per-run truth source for what settings were supposed to be active, even if they are identical across participants.

session_snapshot.json

This is the richer machine-readable session-condition snapshot for QC and forensic review. It should bundle:

  • the full session_settings.json payload
  • the companion-side view of the pinned headset/app/device-profile state
  • the live Sussex twin-state snapshot captured when the run starts
  • the effective visual-profile state
  • the effective controller-breathing profile state

The goal is that a later reviewer can open a single JSON file in the Windows session folder and reconstruct the exact session conditions without needing the headset online.

The pulled Quest session should now mirror the same idea on-device:

  • Quest session_settings.json remains the compact file/index for row counts, file paths, app identity, and recording metadata.
  • Quest session_snapshot.json is the richer runtime-side snapshot and should include the active study snapshot entries, current runtime config summary, active capture/payload profile, and the resolved hotload bindings that define the APK-side experiment conditions.

Participant Locked Mode

Participant locked mode is the Sussex runtime mode used during an actual participant run after tuning is complete.

It should reduce live and Quest-side overhead by disabling the broad legacy Quest CSV matrix and the verbose twin-state diagnostics that are useful during tuning, while preserving:

  • the Windows-side signals_long.csv and breathing_trace.csv recorder output
  • the Quest-side signals_long.csv and breathing_trace.csv
  • the Quest-side session_events.csv, session_settings.json, and session_snapshot.json
  • the study snapshot keys needed for breathing, coherence, sphere radius, LSL timing/counters, session state, and headset/controller pose

That means participant locked mode is a live-telemetry reduction, not a data retention reduction.

Suggested Implementation Order

  1. Lock the Sussex workflow and hazard rules in the GUI copy and docs.
  2. Add the fixed readiness gate and participant-number flow in the WPF shell.
  3. Add runtime command ids and telemetry keys in the participant-facing runtime.
  4. Mirror the updated Sussex APK and extend samples/study-shells/sussex-university.json.
  5. Build the recorder and per-participant storage.
  6. Add brightness and volume only after live readback is proven stable.
  7. Extend the verification harness to cover the new fixed flow.

Current Code Touchpoints

  • src/ViscerealityCompanion.App/ViewModels/StudyShellViewModel.cs
  • src/ViscerealityCompanion.App/StudyShellView.xaml
  • src/ViscerealityCompanion.Core/Models/StudyShellModels.cs
  • src/ViscerealityCompanion.Core/Services/StudyShellCatalogLoader.cs
  • src/ViscerealityCompanion.Core/Services/WindowsAdbQuestControlService.cs
  • src/ViscerealityCompanion.Core/Services/LslTwinModeBridge.cs
  • samples/study-shells/sussex-university.json