Use this page when ACC is already streaming and you want a reliable breathing calibration, state readout, and fast failure checklist.

The Breathing tab is the app surface for the ACC-only breathing-volume approximation. It exposes the tracker state, live telemetry, calibration commands, and tuning parameters that were ported from the existing Unity-side runtime.

This tracker is repository-specific code, not a cited external method paper. It has not yet been externally validated, and a validation study is actively being worked on.

Open formula sheet Download Markdown Download PDF

What The Page Exposes

  • live output volume plus the current inhale/exhale/pause state
  • tracker state such as transport connected, calibrated, calibrating, and bad tracking
  • calibration commands for Start calibration, Cancel, and Reset tracker
  • tuning controls for the default app settings and a live Flip inhale/exhale action
  • telemetry for sample rate, useful-signal detection, bounds, axis, center, current volumes, and last calibration failure

Manual App Test

  1. Wear the strap and wet the electrodes.
  2. Make sure Polar Beat, Polar Flow, or any other BLE client is not connected to the same H10.
  3. Start the app and connect to the intended strap.
  4. Confirm the main session comes up clean:
    • connection state moves to Connected or Streaming
    • HR updates begin
    • ACC frame counts increase on the Live tab
  5. Open the Breathing tab.
  6. Check the top status line:
    • before calibration it should report an uncalibrated or bad-tracking state
    • sample-rate and last-sample telemetry should update once ACC is flowing
  7. Press Start calibration.
  8. Breathe normally for the full calibration window without touching the strap.
  9. Confirm calibration completes:
    • Calibrated should become true
    • the breathing chart should start moving
    • state should move between Inhaling, Exhaling, and Pausing
  10. Use Flip inhale/exhale if the state direction is reversed for your strap orientation.
  11. Adjust tuning only if needed:
    • use Apply tuning when you want a clean reset with new parameters
    • use Restore defaults to go back to the app defaults
  12. If the signal becomes unreliable, inspect:
    • Useful signal
    • Axis range
    • Tracking
    • Last failure

Fast Failure Checks

  • If Sample rate stays low or Last sample is stale, ACC is not reaching the tracker.
  • If Useful signal remains false after calibration, the strap motion on the chosen axis is too small for the current thresholds.
  • If the chart moves but inhale/exhale is reversed, use Flip inhale/exhale instead of recalibrating.
  • If Last failure mentions travel or sample-count limits, rerun calibration while breathing more clearly through the full window.

Desktop App Run Paths

The canonical repo-local desktop build is:

powershell -ExecutionPolicy Bypass -File .\tools\app\Build-Workspace-App.ps1
.\out\workspace-app\PolarH10.App.exe

If Windows application-control policy blocks that normal multi-file workspace launch, publish a single-file fallback instead:

dotnet publish src/PolarH10.App/PolarH10.App.csproj `
  -c Release `
  -r win-x64 `
  -p:PublishSingleFile=true `
  -p:SelfContained=false `
  -o out/app-single

Then launch:

.\out\app-single\PolarH10.App.exe

Related Pages