Data Path
- input stream: accepted RR intervals from live BLE heart-rate measurement packets
- physical H10: RR intervals are derived inside the strap from ECG beat timing
- synthetic transport: RR remains the source for the HRV solve, while synthetic PMD ECG is emitted on the same synthetic beat schedule for operator review
Rolling Short-Term Window
The app uses a rolling RR window with a default length of 300 s. That default
tracks the conventional short-term setting discussed by Shaffer and Ginsberg.
The first solve is intentionally delayed until the rolling window is nearly full enough to avoid publishing an early headline value from a partial capture.
Time-Domain Formulas
For accepted RR intervals NN_1 ... NN_n:
Here NN_i means the i-th accepted beat interval in milliseconds, n is the
number of accepted intervals in the current rolling window, and an overline
means a window average. These formulas are applied to the accepted short-term
series the tracker keeps for the HRV solve, not to every raw packet value.
This is the average accepted beat interval over the current short-term window.
This converts the mean interval into beats per minute using 60000 ms = 1 min.
SDNN measures how widely the accepted intervals are spread across the whole
window.
RMSSD focuses on beat-to-beat change by differencing neighboring intervals
before averaging.
\ln RMSSD is the natural-log form of RMSSD; it compresses the scale and is
often easier to compare across sessions.
pNN50 is the percentage of adjacent interval pairs whose absolute difference
exceeds 50 ms.
SD1 is the short-axis Poincare equivalent of short-term variability and is
shown because many readers know HRV through that geometric view.
Alignment Status
The implementation is aligned to the cited short-term HRV guidance for:
RMSSDas the headline short-term vagally weighted metricSDNNas sample standard deviation over the accepted short-term windowpNN50with a fixed50 msthresholdSD1 = RMSSD / sqrt(2)mean NN,mean HR, andlnRMSSD
The app does not claim to reproduce:
24 hnorms- clinical artifact adjudication
- full Holter-style NN editing
It is therefore documented as short-term RR-derived telemetry rather than a clinical HRV workstation.